Background: Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. Objective: To evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. Methods: Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included pre-operative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. Results: Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission, and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. Conclusions: Our findings demonstrate safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.

Chirag Barbhaiya

and 7 more

Our article reported risk factors for ICD lead failure at our medical center, and we found an elevated risk of ICD lead failure in multiple lead ICD systems implanted via cephalic venous access.(1) Our analysis was prompted by recent literature related to durability of the Linox ICD lead (Biotronik, Inc., Berlin, Germany), and we found similar, elevated risk of ICD lead failure implanted in multiple lead systems via cephalic access in Linox and non-Linox ICD leads. Given the small number of total lead failures in the overall cohort (6 of 660), and the retrospective, single-center nature of our analysis, we reviewed prior Linox ICD lead durability manuscripts for evidence of increased risk of failure in multiple lead ICD systems implanted via cephalic venous access. While no prior manuscript evaluated this specific risk, we did find a trend towards increased risk of lead failure in cohorts with greater proportions of multiple lead systems, and greater proportions of systems implanted via cephalic access, however these variables were included in the analysis in a minority of prior studies.Dr. Maas and colleagues express surprise at the high failure rate when implanting multiple leads in our cohort. We would clarify that we reported ICD lead failure in 4 of the 304 patients in our cohort with multiple ICD leads, and that the frequency of lead failure in multiple lead ICD systems was not statistically significantly different compared to that of single lead ICD systems. In contrast, and surprisingly to us, 3 of 30 patients with multiple lead ICD systems implanted via cephalic access experienced ICD lead failure, and the frequency of ICD lead failure was significantly greater in this group compared to the remaining cohort in Kaplan-Meier survival analyses.Maas and colleagues question the reason for utilization of cephalic access in 18% of patients, hypothesize that suboptimal implantation technique may be responsible for the elevated lead failure rate, and request clarification of lead failure mechanism. We did not systematically collect rationale for venous access technique, and venous access techniques was at the discretion of the implanting physician. Of the 6 lead failures, 3 were related to lead noise, and 3 were related to rising pacing thresholds. Of the three lead failures amongst patients with multiple lead systems implanted via cephalic venous access, 2 were related to lead noise, and 1 was related to a rising pacing threshold. We believe that the lead noise may be related to insulation breach that may be predisposed by lead-lead interactions in the region of the cephalic vein. ICD leads were returned to the manufacturer on an ad hoc basis, and no specific feedback was received from manufacturers related to leads included in our analysis. All implanting physicians were experienced operators, and there were no significant differences in frequency of ICD lead failure by operator. We agree that implantation technique may play an important role in lead failure risk, and our analysis should prompt extra caution when implanting multiple leads via cephalic venous access.Citing the above limitations of our analysis, Dr Maas and colleagues state that it is “too early to abandon cephalic vein access, even for multiple lead systems.” They also review recent literature reporting favorable acute outcomes of ultrasound guided axillary venous access. We agree that our analysis paired with our literature review is best considered hypothesis generating, and we hope that our analysis encourages future studies to consider our findings when selecting variables of interest in ICD lead durability studies. We share Dr. Maas and colleagues’ favorable view of data supporting axillary venous access, particularly in combination with ultrasound guidance. As a result, given the available evidence of acceptable alternative techniques, our practice is to favor axillary venous access during implantation of multiple lead ICD systems, but we would not hesitate to implant via cephalic venous access in the appropriate clinical scenario.References1. Barbhaiya CR, Niazi O, Bostrom J et al. Early ICD lead failure in defibrillator systems with multiple leads via cephalic access. Journal of cardiovascular electrophysiology 2020;31:1462-1469.

Matthew Dai

and 10 more

Background: Improved catheter stability is associated with decreased arrhythmia recurrence after atrial fibrillation (AF) ablation. Recently, atrial voltage mapping in AF was demonstrated to correlate better with scar as compared to mapping in sinus rhythm (SR). However, it is unknown whether ablation of persistent AF in sinus rhythm with atrial pacing or in atrial fibrillation with ventricular pacing results in differences in catheter stability or arrhythmia recurrence. Methods: We analyzed 53 consecutive patients undergoing first-time persistent AF ablation with pulmonary vein and posterior wall isolation: 27 were cardioverted, mapped, and ablated in sinus rhythm with atrial pacing, and 26 were mapped and ablated in AF with ventricular pacing. Ablation data was extracted from the mapping system and analyzed using custom MATLAB software to determine high-frequency (60Hz) catheter excursion as a novel metric for catheter spatial stability. Results: There was no difference in catheter stability as assessed by maximal catheter excursion, mean catheter excursion, or contact force variability between the atrial-paced and ventricular-paced patients. Ventricular-paced patients did have significantly greater mean contact forces compared to atrial-paced patients. One year arrhythmia-free survival was similar between the atrial paced and ventricular paced patients (78% vs 67%, p = 0.31). Conclusion: For patients with persistent AF, ablation in AF with ventricular pacing results in similar catheter stability and arrhythmia recurrence as compared to cardioversion and ablation in sinus rhythm with atrial pacing. Given the improved fidelity of mapping in AF, mapping and ablating during AF with ventricular pacing may be preferred.