Title: Percutaneous Lead Extraction in Patients with Large Vegetations: Limiting our Aspirations.Robert D. Schaller, DO11The Section of Cardiac Electrophysiology, Cardiovascular Division, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, PennsylvaniaFunding: This work was supported in part by the Mark Marchlinski EP Research & Education FundKey words: Lead extraction, vegetation, pulmonary embolism, thrombus, aspirationDisclosures: NoneWord count: 1547Transvenous lead extraction (TLE) in the 1960’s involved orthopedic-style pulley systems that joined the exposed portion of the lead to progressively heavier weights hanging from the bed. Sustained tension on the lead was maintained until the patient experienced discomfort, ventricular arrhythmias, or noticeable resistance developed, and was maintained for minutes to days. The location of the lead within the chest was monitored with daily chest radiographs and the ensuingbang of the weight hitting the floor of the intensive care unit signified case conclusion; at which point the patient was assessed. Complications were erratic and included lead laceration and possible migration, injury to the tricuspid valve (TV), myocardial avulsion, tamponade, and death.1 Due to the immature nature of the procedure at that time, it was relegated to infectious indications including lead-related endocarditis, at that time referred to as “catheter fever”.Contemporary TLE has evolved into a highly refined practice with a multitude of tools and predictable results, and procedural indications that now span infection, venous occlusion, management of redundant leads, and access to magnetic resonance imaging.2Procedural imaging with computed tomography (CT) and real-time ultrasound-based tools have similarly changed the TLE experience with identification of adhesions, thrombi, vegetations, and complications.3 Large lead-related masses have historically caused angst due to the possibility of being sheared off by the extraction sheath and embolizing to the lung, and still represent a relative contraindication to percutaneous TLE.2In this issue of the Journal of Cardiovascular Electrophysiology , Giacopelli, et al.4 present the outcomes of 25 consecutive patients (mean age 64 years, 68% male) including 5 with pacemakers, 10 with implantable cardioverter-defibrillators, and 10 with cardiac resynchronization therapy devices, who underwent TLE with vegetations ≥10 mm on transesophageal echocardiography (TEE). Contrast-enhanced CT was performed before and after TLE with 18 (72%) patients showing subclinical pulmonary embolism (PE). Vegetation size (median of 17.5 mm and maximum of 30 mm) did not differ in those with and without PE (20.0 mm vs. 14.0 mm, p=0.116). Complete TLE success was achieved in all patients with 76% requiring advanced tools and 2 needing femoral snaring, and there were no significant procedural complications. In the group with pre-TLE PE, a post-TLE scan confirmed the presence of PE in only 14/18 (78%) and there were no patients with new PE formation. During a median follow-up period of 19.4 months, no re-infection of the new implanted systems was reported and there were 5 deaths (20%); with no differences between the groups. The authors concluded that subclinical PE was common in this clinical scenario but did not influence the complexity or safety of the procedure.Several aspects of this paper warrant comment. No data are reported on the size or location of the PEs nor the time between the first and second CT. It is possible that small PEs would not be identified on subsequent studies days after antibiotics had already been started. Patients also received acute and chronic anticoagulation if PE was identified, which in the setting of vegetations, is generally not indicated and could potentially lead to bleeding. The authors did not provide information regarding infectious pathogens or the timing of culture clearance, which could influence treatment. Additionally, it is unclear which patients received new CIED systems including the type and timing of reimplantation, which might influence subsequent infectious risk. A vascular occlusion balloon was not used in any patients in this report. While this tool is associated with a reduced risk of death in the setting of a superior vena cava laceration when used properly, it has also been shown to be thrombogenic during long dwell times,5 and use could impact post-operative CTs in future studies. Despite utilizing transthoracic echocardiography during TLE, neither TEE nor intracardiac echocardiography were used intraoperatively and thus no information regarding the precise location of the vegetations within the heart is known. Importantly, no information regarding the characteristics of the vegetations other than size was reported.Not all lead-related masses are created equal with two distinct sub-types previously described.6 The first is composed of thickened endocardium and fibrous tissue covering the leads and ultimately forming into connective tissue. These masses, commonly found on leads behind the TV, are caused by a vortical flow pattern leading to low shear stress on the lead surface and provoking neointimal hyperplasia,7 and range from small fibrous strands to large, smooth organized thrombus (Figure, left column). Despite their sterile nature, TLE in the setting of a large, mature thrombus could result in embolization and obstruction of the pulmonary artery resulting in symptomatic PE. The second type, frequently seen in the setting of infective endocarditis, is composed of inflammatory cells, platelets, adhesion molecules, fresh fibrin, and bacteria binding to coagulum and forming vegetations. They are typically longer, more likely to be multi-lobular, and commonly span several chambers of the heart (Figure, right column). These vegetations that are typically acute, with friable finger-like projections, characteristically break apart upon being sheared off during TLE, with reports showing low risk of symptomatic PE.8 Vegetations that are lobular, however, have been associated with worse outcomes.9Despite acute procedural success in the setting of lead-related vegetations, mortality rates at 1 year approach 25%.10 Indeed, despite successful TLE in this report, 20% of patients were dead at 1.5 years. Although complete understanding of the mechanism of these poor outcomes remains unknown, septic emboli, lung abscesses, and infected lead “ghosts” have been implicated.11 Vegetation removal prior to TLE has thus represented an appealing therapeutic option with reports of successful percutaneous aspiration prior to TLE showing promising results, albeit with unknown long-term benefit.12,13 Although the lack of new PEs after TLE in this report does not directly support the effort, cost, and added risk of such a strategy, “debulking” of infectious burden remains a tempting complementary treatment. Importantly, the acute safety of TLE with large vegetations in this study should not be extrapolated to chronic, large lead-related masses, which are more like to cause acute PE if embolized. While aspiration of these sterile masses prior to TLE is appealing from a procedural outcome perspective, their morphologic characteristics, and the imperfect, but evolving, aspiration sheaths currently available are limiting, and requires consideration of surgical extraction. Further advancements in aspiration catheter technology and the development of right ventricular outflow track filters might influence future management.TLE continues to represent the gold standard for the management of lead-related infection.2 Due to the extensive work of the pathfinders in the vanguard of procedural development, the sound of crashing weights has been supplanted by those that power advancing sheaths. Yet despite the safe and predictable nature of modern-day TLE, the sobering long-term mortality of patients with infectious indications remains out of proportion to acute procedural success. While infectious “debulking” continues to represent the most attractive and practical complementary option to address this incongruity, future studies should concentrate both on identification of mass characteristics that suggest success, as well as determining if long-term benefits exist above and beyond lead removal. However, if improvement in clinical outcomes that warrant this added cost and effort are not identified, we should likely limit our aspirations.
Background: The subcutaneous implantable-cardioverter defibrillator (S-ICD) is an appealing alternative to transvenous ICD systems. However, data on indications for S-ICD explantations are sparse. Objectives: To assess incidence and indications for S-ICD explantation at a large tertiary referral center. Methods: We conducted a retrospective study of all S-ICD explantations performed from 2014 to 2020. Data on demographics, comorbidities, implantation characteristics, and indications for explantation, were collected. Results: A total of 64 patients underwent S-ICD explantation during the study period. During that time, there were 410 S-ICD implantations at our institution of which 53 (12.9%) were explanted with a mean duration from implant to explant of 19.7±20.1 months. The mean age of the patients at explantation was 44.8±15.3 years, and 42% (n=27) were female. The indication for S-ICD implantation was primary prevention in 58% and secondary prevention in 42% of the patients. The most common reason for explantation was infection (32.8%) followed by abnormal sensing (25%) and need for pacing (18.8%). Those who underwent S-ICD explantation for pacing indications were significantly older (55.7±13.6 vs 42.3± 14.6 years, p = 0.005) with a wider QRS duration (111±19 ms vs 98±19 ms, p = 0.03) at device implantation compared to patients who underwent explantation for other indications. Conclusion: Incidence of S-ICD explantation in a large tertiary practice was 12.9%. While infection was the indication for a third of the explantations, a significant number were due to sensing abnormalities and need for pacing. These data may have implications for patient selection for S-ICD implantation.

Oscar Cano

and 12 more

Introduction: Conduction system pacing (CSP) has emerged as an ideal physiologic pacing strategy for patients with permanent pacing indications. We sought to evaluate the safety and feasibility of CSP in a consecutive series of unselected patients with congenital heart disease (CHD). Methods: Consecutive patients with CHD in which CSP was attempted were included. Safety and feasibility, implant tools and electrical parameters at implant and at follow-up were evaluated. Results: A total of 20 patients were included (10 with a previous device). Ten patients had complex forms of CHD, 9 moderate defects and 1 a simple defect. His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) were achieved in all patients (10 HBP, 5 LBBP and 5 left ventricular septal pacing). Procedure times and fluoroscopy times were prolongued (126±82 min and 27±30 min, respectively). CSP lead implant times widely varied ranging from 4 to 115 minutes, (mean 31±28 min) and the use of multiple delivery sheaths was frequent (50%). The QRS width was reduced from 144±32 ms at baseline to 116±16 ms with CSP. Implant electrical parameters included: CSP pacing threshold 0.85±0.61V; R wave amplitude 9.8±9.2mV and pacing impedance 735±253 Ohms, and remained stable at a median follow-up of 478 days (IQR 225-567). Systemic ventricle systolic function and NYHA class (1.50±0.51 vs 1.10±0.31; p=0.008) significantly improved at follow-up. Lead revision was required in one patient at day-4. Conclusions: Permanent CSP is safe and feasible in patients with CHD although implant technique is complex.